| SYS-4028GR-TR2 | 
SuperServer 4028GR-TR2 (Black) |  
|  |  
 
|  |  
| Super X10DRG-O+-CPU
 |  
|  |  
 
|  |  
| CPU | 
Intel® Xeon® processor E5-2600 v4†/ v3 family (up to 160W TDP) Dual Socket R3 (LGA 2011) |  
| Cores / Cache | 
Up to 22 Cores† / Up to 55MB† Cache |  
| System Bus |  |  
| Note | † BIOS version 2.0 or above is required |  
|  |  |  
|  |  
 
|  |  
| Memory Capacity | 
24x 288-pin DDR4 DIMM slotsUp to 3TB† ECC 3DS LRDIMM, 1.5TB ECC RDIMM |  
| Memory Type | 
2400†/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit |  
| DIMM Sizes | 
RDIMM: 64GB, 32GB, 16GB, 8GB, 4GBLRDIMM: 64GB, 32GB3DS LRDIMM: 128GB |  
| Memory Voltage |  |  
| Error Detection | 
Corrects single-bit errors |  
|  |  
 
|  |  
| Chipset |  |  
| SATA | 
SATA3 (6Gbps) with RAID 0, 1, 5, 10 |  
| IPMI | 
Support for Intelligent Platform Management Interface v.2.0IPMI 2.0 with virtual media over LAN and KVM-over-LAN supportASPEED AST2400 BMC |  
| Network Controllers | 
Dual Gigabit Ethernet Ports with Intel® i350Virtual Machine Device Queues reduce I/O overheadSupports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output |  
| Graphics |  |  
|  |  
 
|  |  
| SATA |  |  
| LAN | 
2 RJ45 Gigabit Ethernet LAN ports1 RJ45 Dedicated IPMI LAN port |  
| USB |  |  
| Video |  |  
| Serial Port |  |  
|  |  
 
|  |  
| BIOS Type | 
128Mb SPI Flash EEPROM with AMI® BIOS |  
| BIOS Features | 
Plug and Play (PnP)APM 1.2DMI 2.3PCI 2.3ACPI 1.0 / 2.0 / 3.0USB Keyboard supportSMBIOS 2.7.1UEFI |  |  | 
|  |  
 
|  |  
| Form Factor | 
4U RackmountableRackmount Kit (MCP-290-00057-0N) |  
| Model |  |  
|  |  
 
|  |  
| Height |  |  
| Width |  |  
| Depth |  |  
| Weight | 
Net Weight: 65.5 lbs (29.7 kg)Gross Weight: 100 lbs (45.3 kg) |  
| Available Colors |  |  
|  |  
 
|  |  
| Hot-swap | 
24 Hot-swap 2.5" hard drive bays |  
|  |  
 
|  |  
| PCI-Express | 
11 PCI-E 3.0 x16 (FH, FL) slots1 PCI-E 3.0 x8 (in x16) slotsSingle Root Complex |  
|  |  
 
|  |  
| SAS/SATA HDD Backplane |  
|  |  
 
|  |  
| Fans | 
8 Hot-swap 92mm cooling fans |  
| Shrouds | 
1 Air Shroud (MCP-310-41808-0B) |  
|  |  
 
| 2000W Redundant Power Supplies with PMBus |  
| Total Output Power |  |  
| Dimension (W x H x L)
 |  |  
| Input | 
100-120Vac / 12.5-9.5A / 50-60Hz200-220Vac / 10-9.5A / 50-60Hz220-230Vac / 10-9.8A / 50-60Hz230-240Vac / 10-9.8A / 50-60Hz200-240Vac / 11.8-9.8A / 50-60Hz (UL/cUL only) |  
| +12V | 
Max: 83.3A / Min: 0A (100-120Vac)Max: 150A / Min: 0A (200-220Vac)Max: 165A / Min: 0A (220-230Vac)Max: 166.7A / Min: 0A (230-240Vac)Max: 166.7A / Min: 0A (200-240Vac) (UL/cUL only) |  
| 12Vsb |  |  
| Output Type | 
25 Pairs Gold Finger Connector |  
| Certification |   UL/cUL/CB/BSMI/CE/CCC Titanium Level
 [ Test Report ]
 |  
|  |  
 
|  |  
| CPU | 
Monitors for CPU Cores, +1.2V, 1.5V, +3.3V, +12V, (+3V, 1.0V, 1.2V, 1.8V, 1.1V) Standby, VBAT, Memory, Chipset Voltages.4-Phase-switching voltage regulator with auto-sense from 0.6V-1.35V |  
| FAN | 
4-pin fan headers with tachometer status monitoringLow noise fan speed control mode |  
| Temperature | 
Monitoring for CPU and system environmentThermal Control for 8 fan connectors |  
| Other Features | 
Chassis intrusion detection |  
|  |  
 
|  |  
| RoHS |  |  
| Environmental Spec. | 
Operating Temperature: 10°C to 35°C (50°F to 95°F)
Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
 |  |